  Datasheet File OCR Text:
  specification model dc voltage rated current current range rated power output voltage adj. range line regulation load regulation setup, rise time hold up time (typ.) voltage range note.5 frequency range power factor (typ.) efficiency(typ.) ac current (typ.) input inrush current (typ.) leakage current safety standards working temp. working humidity storage temp., humidity temp. coefficient vibration mtbf dimension others note packing overload 1500ms, 50ms at full load 20ms at full load 88 ~ 264vac 124 ~ 370vdc 47 ~ 63hz 84% 79% 85% 85% 86% 86% 6.8a/115vac 3.4a/230vac 20a/115vac 40a/230vac <1.3ma/240vac 105 ~ 135% rated output power protection type : constant current limiting, recovers automatical ly after fault condition is removed ul60950-1, tuv en60950-1 approved -20 ~ +60 (refer to output load derating curve) 20 ~ 90% rh non-condensing -40 ~ +85 , 10 ~ 95% rh 0.03%/ (0 ~ 50 ) 10 ~ 500hz, 2g 10min./1cycle, period for 60min. each along x, y, z axes 116.4k hrs min. mil-hdbk-217f (25 ) 170*120*93mm (l*w*h) file name:psp-600-spec 2010-10-18 12v 5v 13.5v 15v 24v 27v 50a 80a 44.5a 40a 25a 22.2a 12.5a 0 ~ 50a 0 ~ 80a 0 ~ 44.5a 0 ~ 40a 0 ~ 25a 0 ~ 22.2a 0 ~ 12.5a 600w 400w 600w 600w 600w 600w 600w 240mvp-p 180mvp-p 240mvp-p 240mvp-p 240mvp-p 240mvp-p 300mvp-p 10 ~ 13.2v 4.75 ~ 5.5v 12 ~ 15v 13.5 ~ 18v 20 ~ 26.4v 24 ~ 30v 41 ~ 56v 1.0% 2.0% 1.0% 1.0% 1.0% 1.0% 1.0% 0.5% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% psp-600-12 psp-600-5 psp-600-13.5 psp-600-15 psp-600-24 psp-600-27 psp-600-48 1.9kg; 8pcs/15.5kg/1.06cuft 1. all parameters not specially mentioned are measured at 230vac input, r ated load and 25 of ambient temperature. 2. ripple & noise are measured at 20mhz of bandwidth by using a 12" twisted pair- wire terminated with a 0.1uf & 47uf parallel capacitor. 3. tolerance : includes set up tolerance, line regulation and load regula tion. 4. the power supply is considered a component which will be installed into a fi nal equipment. the final equipment must be re-confirmed that it still me ets emc directives. 5. derating may be needed under low input voltages. please check the derati ng curve for more details. for guidance on how to perform these emc tests, please refer to ?emi testing of c omponent power supplies.? (as available on http://www.meanwell.com) over voltage 13.8 ~ 16.2v 5.75 ~ 6.75v 15.5 ~ 18.2v 18 ~ 21v 27.6 ~ 32.4v 31 ~ 36.5v 57.6 ~ 67.2v universal ac input / full rangebuilt-in active pfc function protections: short circuit / overload / over voltage / over temperature forced air cooling by built-in dc fan with dc ok signal output current sharing up to 2400w(3+1) built-in remote on-off control built-in remote sense function fixed switching frequency at pfc:88khz pwm:100khz 3 years warranty features : withstand voltage isolation resistance i/p-o/p:3kvac i/p-fg:1.5kvac o/p-fg:0.5kvac i/p-o/p, i/p-fg, o/p-fg:100m ohms / 500vdc / 25 / 70% rh environment protection emi conduction & radiation ripple & noise (max.) note.2 voltage tolerance note.3 harmonic current ems immunity compliance to en55022 (cispr22) class b compliance to en61000-3-2,-3 compliance to light industry level, criteria a en61000-4-2,3,4,5,6,8,11; env50204, 0.95/230vac 0.99/115vac at full load safety & emc (note 4) p s p - 6 0 0 s e r i e s protection type : shut down o/p voltage, re-power on to recover remote control pok signal function rc+/rc-: short = power on ; open = power off psu turn on: 3.3v ~ 5.6v psu turn off: 0v ~ 1v over temperature +5v: 95 (tsw1) detect on heatsink of power transistor; 95 (tsw51) detec t on heatsink of power diode +12v ~ +48v: 85 (tsw1) detect on heatsink of power transistor; 80 (tsw51) d etect on heatsink of power diode protection type : shut down o/p voltage, re-power on to recover 600w with pfc and parallel function 87% 48v
file name:psp-600-spec 2010-10-18 mechanical specification derating curve output derating vs input voltage case no.910a unit:mm ambient temperature ( ) input voltage (v) 60hz 115 88 100 135 155 230 264 90 100 80 70 60 50 40 load (%) -20 0 10 20 30 45 40 50 60 (horizontal) 20 40 50 60 80 100 load(%) pwm circuit detection o.l.p. emi filter rectifiers & p.f.c. power switching filter & rectifiers +v -v i/p fg control o.v.p. o.t.p. inrush current active limiting fan o.c.p. rc rc.g. pok control signal current sharing p circuit pfc fosc : 88khz pwm fosc : 100khz 12v others ta=25 rs connector(cn5) : jst b-xh or equivalent pin no. 12 assignment mating housing jst xhp jst sxh-001t or equivalent or equivalent terminal rs+ rs- terminal pin no. assignment pin no. 13 4 5 6 7 8~11 12~15 2 assignment fg p(current share) pok r.c. g r.c. dc output +v dc output -v ac/n ac/l 14 max. p s p - 6 0 0 s e r i e s 600w with pfc and parallel function block diagram 9.5 cn5 11.5 8 11.5 120 15 14 13 12 11 10 9 8 7 6 5 4 3 2 1 170 185 150 150 2-m3 l=4mm max. 93 100 50 58.3 2-m3 l=4mm max. 2-m3 l=4mm max. air flow direction 2-m3 l=4mm max. 1 2
control terminal instruction manual pok signal pok signal is the voltage difference between +v +v +v l l l n n n fg fg fg p p p pok pok pok rcg rcg rcg rc rc rc rs+ rs+ rs+ rs- rs- rs- +v +v +v load load load + + + - - - +v +v +v +v +v +v -v -v -v -v -v -v -v -v -v -v pok(+) rcg(-) -v -v "rcg" and "pok" pin output pok signal for ttl level signal psu turn on: 3.3v ~ 5.6v psu turn off: 0v ~ 1v parallel operation with remote sensing remote sensing power on: rcg and rc for short remote control power off: rcg and rc for open rcg rc load psu psu psu psu + + + + - - - - p p p p rc- rc- rc- rc- rs+ rs+ rs+ rs+ rs- rs- rs- rs- +v +s -v -s (1)parallel operation is available by connecting the units shown as bel ow (+s,-s and p are connected mutually in parallel) : (2)the voltage difference among each output should be minimized that le ss than 2% is required. (3)the total output current must not exceed the value determined by the fol lowing equation (output current at parallel operation) =(the rated current per unit) x (number of unit) x 0.9. (4) in parallel operation 4 units is the maximum, please consult the manuf acture for other applications. (5) when remote sensing is used in parallel operation, the sensing wire mus t be connected only to the master unit. (6) when in parallel operation, the minimum output load should be greater t han 3% of total output load. (min. load > 3% rated current per unit x number of unit) file name:psp-600-spec 2010-10-18 p s p - 6 0 0 s e r i e s 600w with pfc and parallel function


▲Up To Search▲   

 
Price & Availability of PSP-60010

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X